Title reads like at ad, but this is a new way to reach energy independence. I actually have a small EcoFlow device and it’s pretty good for the price.

I hope this tech can be made available in the US soon.

  • Sleepkever@lemm.ee
    link
    fedilink
    English
    arrow-up
    0
    ·
    5 months ago

    The cables in your walls are designed for a certain maximum current before they start to heat up. This current is limited by your breaker.

    Now if you introduce a plug in solar setup your current is limited by your maximum breaker capacity + whatever your solar setup can generate.

    So if I’d use the specs from the article and apply it to a normal dutch home situation: 16A breaker, + 800W at 230V, which means ~3.5A = 19.5A max. which is probably still fine for short durations.

    But now some genius doesn’t read the fine print and hooks up 2 or 3 on the same circuit. There is no electrician that tells him that’s dangerous because it’s all self installed and he doesn’t know any better. And all of a sudden you are up to 26.5A and you got glowing, smoking wires in your walls…

    • Randelung@lemmy.world
      link
      fedilink
      English
      arrow-up
      0
      ·
      5 months ago

      Also, emergency service hazard. The PV won’t turn off if firefighters take out the mains, which makes a house potentially inaccessible during an emergency.

      • Sleepkever@lemm.ee
        link
        fedilink
        English
        arrow-up
        0
        ·
        5 months ago

        Surprisingly, no. Most inverters in the EU must come with island protection. Meaning that if there is no AC from the grid it immediatly switches off the inverter or the battery, there is no stand alone operation.

        There are some systems that allow it but they are rare here and require the mains side to be fed trough the inverter itsself ensuring it’s never back feeding into the grid when there is no power with the same island protection, or less commonly there is a transfer switch of some kind also eliminating the issue. And either should obviously have a main kill switch on the breaker board for emergencies that also switches off the in home power with 1 action.

        But most importantly, either of those options is not plug and play and will require an electrician that hopefully does know what he’s doing.

        • Randelung@lemmy.world
          link
          fedilink
          English
          arrow-up
          0
          ·
          5 months ago

          Does the island protection with if you have two inverters running independently? (legally or not)

          • luckystarr@feddit.de
            link
            fedilink
            English
            arrow-up
            0
            ·
            5 months ago

            Yes, because the frequency of the grid is also a trigger for shutting off the inverter. Inverters generate a frequency which indicates a “non healthy grid” that trigger the shutoff of connected inverters.