Hello folks! Build a MK4 4 months ago and was very happy with it so far. Now I have bed adhesion problems (see pic attached). 3 weeks ago I had similar problems and after a chat with prusa and resetting the calibration / cleaning the build plate again it worked fine. Now the problem is back despite a clean build plate . After resetting the calibration I got one nice print and then the same problem again. Cold pull of the nozzle resulted in a clean tip and no better results, so I do not think there is any clogging. Also the plate and the should be alright, as I got good results inbetween. Any ideas / hints where my problem is? Link leads to image of the problem. Could not upload the file for some reason…
I’d need some more details here.
Stock Nozzle (0.4mm)?
What Filament are you trying to Print?
What did “cleaning the build plate” entail?
Is the nozzle actually clean when the Printer taps the build plate? If not, it may be useful to quickly remove any possible ooze of filament just before the tapping / nozzle cleaning starts.
Glue Sticks are imho super useful for bad bed adhesion. Depends a little on what the Problem and your usecase is though. I like my cheap filaments and don’t often repeat Prints.
Thanks for your answer. I use the 0.4 see stock nozzle trying to use PLA. The plate has been cleaned with 99% isopropanolol and hot water with lots of soap. I am trying to keep the tip of the noozle clean but I like to start prints remotely so I am not always next to it when the bed measuring takes place. Do you watch for that little bit of “ooze” every print? Gluestick might be an option but it worked perfectly before without on the same plate with the same filament.